To enable SNMPv2 access on the Enterasys C2 Switches you have to issue following commands:


         set snmp access gReadOnlyV1V2C security-model v1 exact read vUnsecured
         set snmp access gReadOnlyV1V2C security-model v2c exact read vUnsecured
         set snmp community mycomunity securityname sn_v1v2c_ro
         set snmp group gReadOnlyV1V2C user sn_v1v2c_ro security-model v1
         set snmp group gReadWriteV1V2C user sn_v1v2c_rw security-model v1
         set snmp group gReadOnlyV1V2C user sn_v1v2c_ro security-model v2c
         set snmp group gReadWriteV1V2C user sn_v1v2c_rw security-model v2c
         set snmp view viewname vUnsecured subtree 1
         set snmp view viewname vUnsecured subtree 0.0